1 Inductive sensor NJ4-12GM50-WS-V12 - Pepperl+Fuchs

General specifications. Switching element function. AC. NO. Rated operating distance sn. 4 mm. Installation non-flush. Output polarity. AC. Assured operating distance sa. 0 ... 3.24 mm. Reduction factor rAl. 0.4. Reduction factor rCu. 0.4. Reduction factor r304. 0.7. Nominal ratings. Operating voltage. UB. 20 ... 253 V.
175KB Größe 20 Downloads 315 Ansichten
Inductive sensor

NJ4-12GM50-WS-V12 Dimensions

60

38

4

5

M12x1

17 S

LED

Model Number NJ4-12GM50-WS-V12

Features •

2-wire AC

Technical Data

Connection 2

General specifications Switching element function Rated operating distance Installation Output polarity Assured operating distance Reduction factor rAl Reduction factor rCu Reduction factor r304 Nominal ratings Operating voltage Switching frequency Voltage drop

L

3

N

1

Pinout

1

2

3

Release date: 2012-11-15 11:59 Date of issue: 2012-11-15

026583_eng.xml

Wire colors 1 2 3

GN (green) RD/BK (red/black) RD/WH (red/white)

Momentary current (20 ms, 0.1 Hz) Operating current Off-state current Time delay before availability Indication of the switching state Ambient conditions Ambient temperature Mechanical specifications Connection type Housing material Sensing face Protection degree Note

sn sa

AC NO 4 mm non-flush AC 0 ... 3.24 mm 0.4 0.4 0.7

UB f Ud

20 ... 253 V 0 ... 20 Hz typ. 4 V at 15 ... 200 mA typ. 6.5 V at 5 mA 0 ... 1200 mA

IL Ir tv

5 ... 200 mA typ. 0.7 mA ≤ 30 ms LED, yellow -25 ... 70 °C (-13 ... 158 °F) Device connector 1/2"-20 UN , 3-pin Stainless steel 1.4305 / AISI 303 PBT IP67 1) In the temperature range below 0 °C, permissible operating voltage Ub 80...253 V Safety fuse ≤ 0.8 A (quick-blow) according to IEC 60127-2 Sheet 1 Recommendation: after a short circuit, check that the device is functioning correctly.

General information Scope of delivery 2 self locking nuts in scope of delivery Compliance with standards and directives Standard conformity Standards

EN 60947-5-2:2007 IEC 60947-5-2:2007

Approvals and certificates UL approval CSA approval CCC approval

cULus Listed, General Purpose cCSAus Listed, General Purpose Certified by China Compulsory Certification (CCC)

Accessories BF 12 Mounting flange, 12 mm

Subject to modifications without notice Pepperl+Fuchs Group USA: +1 330 486 0001 www.pepperl-fuchs.com [email protected]

Germany: +49 621 776-4411 [email protected]

Copyright Pepperl+Fuchs Singapore: +65 6779 9091 [email protected]

1